Incinerator YD-100 for Iraq
There are 03 sets Model YD-100 delivery to Iraq between year 2013 to 2014. The incinerator use for local several...
There are 03 sets Model YD-100 delivery to Iraq between year 2013 to 2014. The incinerator use for local several...
Incinerator Model YD-30 for Australia Melbourne customer. Medical Environmental WWW.HICLOVER.COM Waste Incinerators Medical Waste Incinerator Pet Animal Cremation Solid Waste Incinerator...
Types of incinerator design acceptable: Dual-chamber controlled air incinerator or dual- chamber pyrolytic incinerator Materials of construction: The incinerator will...
news from: http://www.chinadaily.com.cn/a/202002/01/WS5e347a86a310128217273ead.html WHO declares outbreak constitutes international public health crisis China vowed on Friday to work with the international community...
a DUCK farm incinerator, We Have to buy a medium size incinerator for biological waste, more Particular DUCKS.a pet crematorium...
News from: https://www.thestar.com.my/news/nation/2020/01/26/wuhan-virus-china-mobilises-medical-teams-to-fight-new-coronavirus WUHAN (Bernama): China is mobilising medical staff to aid Wuhan, the centre of the novel coronavirus (2019-nCoV) outbreak,...
installation of waste disposable system in airport.Incinerator with oil burner – The layout should prevent any discharge of polluting substances...
50kgs per hour incinerator with two chambers suppliers from china *Aveage 50kgs per hour *Double chamber and double burner *900liters...
30kgs per hour(average) medical waste incinerator, design dual combustion chambers(primary chamber and secondary chamber), smoke filter chamber, PLC auto. control...
The tenderer shall provide hydrostatic oil contents gauge (level index ) or a Centre line near the outlet connection. iv) ...
Waste Incinerator Door: Side/Front Opening Door VS. Top Opening Door Things Side Loading Door Top Loading Door Reference Price Cheap...
The incinerator will have chimney, castable high quality refractory liner and incinerator shell, perforated blind for the primary and secondary...
This equipment quality structural for kinds of site, like hospital, environmental department, animal cremation agencies, etc. HICLOVER Incinerator supply updated...
•Draft Equipment Sulphur Dioxide (SO2): 45 ppmv, 12-hour average as measured by a CEMS; 1Provide a sectional, circular cross section...
Incinerator Model A1500, Overview This model is big-scale animal cremation equipment for big animals. Construction is dual/double combustion chamber with...
Animal Crematory Incinerator Capacity: Average 80kgs per feeding Thing Specification Model A900 Internal Dimensions 120 x 90 x 85 CM...
Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Gal annealed) by Hot-Dip Process FM GLOBAL (FM) SECTION 11 82 21 Page 6...
This model is small-scale waste incineration equipment for small waste output. Construction is dual/double combustion chamber with 02 units oil/gas...
We strive for a sustainable development therefore we are adopting a sustainable medical waste management system, including building a modern...
Oil tank with 2000Liters capacity Items/Model TS150(PLC) Picture Principle Waste Incineration Treatment Burn Rate Average 100-150 kg/hour Feed Capacity Average...
Eductor air. Cooling of exhaust gases from 900 -- 1000 0 C to around 350 0 C. IV. Eductor Assembly...
Incinerator Model CA100, Overview 100Kg/Hour Burning rate with Secondary burning Capacity combustion chamber with 02 units oil burner, batch load incineration...
Waste Incineration Treatment Burn rate (rate of waste incineration) -at least 50 kg per hour Oil tank smoke filter chamber Items/Model...
General The chimney will have a minimum height of 4 meters above ground level; One year Spare Parts Package for...
HICLOVER incinerator exert the advantages and discard the disadvantages of the same kind of equipment at domestic and abroad. It is...
Double Combustion Chamber,Double Italy Burner,Smoke Filter Included,Burning Rate: 50-200kgs per hour optional,Primary Combustion Chamber: 1.57M3(1570Liters),Incinerator Mainbody steel: 8mm thickness,Paint for...
Primary combustion Burn Rate 50kg/h minimum Weight (kg), please indicate: Secondary Chamber Gas Retention Time – 2 Seconds Fuel –...
Containerized Incinerator is one type of mobile incinerator. we build the incinerator and mounted the incinerator into shipping container(20′ container...
Key Features: — Full range incinerator with Economized Small Scale incinerator, Standard Small-Large Scale incinerator, General Municipal Solid Waste Incinerator, ...
Waste Incinerator Model TS150 PLC, Overview Construction is dual/double combustion chamber with 02 sets oil burner, batch load incineration equipment....
Incinerator dimensions: max 2000x1200x3200 mm Charging rate: Gas:- Natural Gas Gasified incineration for burning medical wastes. Gas type: Natural...
Waste Incinerator Model TS150 PLC, Overview Construction is dual/double combustion chamber with 02 sets oil burner, batch load incineration equipment....
Ability per day around 8-10 kg wastage/day. · Which product do you provide, only incinerator or also compactor, shredder machine,...
Average 50-100 kg/hour Burn Rate Items/Model TS75(PLC) Principle Waste Incineration Treatment Burn Rate Average 50-100 kg/hour Feed Capacity Average 200-300...
Incinerator Model TS250 PLC, Overview This model is small-scale waste incineration equipment for small waste output. Construction is dual/double combustion...
50 to 60kg/hr and 100 into 120kg/hr diesel powered incinerator.1. 2. Required Incinerating Capacity: Approximately 4,500 tons per year. The...
Waste is thermally decomposed in the primary chamber at temperatures of 800 °C +. The resulting gaseous products are completely...
incinerate mainly pharmaceuticals ( all types of dosage forms … syrups, tablets, injectables ) medical consummabables, and also biological fluids...
Medium Unit – to handle an average waste production of 500 kg/day.Minimum load capacity: 600 kg.Maximum load capacity: 1,000 kg.Nominal burning rate: 55-80 kg/hr (= 440 C 640kg range per 8hour day). Items/Model TS50(PLC) Picture Principle Waste Incineration Treatment Burn Rate Average 50-100 kg/hour Feed Capacity Average 200-300 kg/feeding Control...
We supply Double Chamber Incinerator with primary chamber size average 1570Liters and burnning rate 50kgs per hour,100kgs per hour,150kgs per hour,200kgs per hour....
TECHNICAL SPECIFICATIONS: COMBUSTION CHAMBER VOLUME (M3); 0.54 m3. SUGGESTED BATCH SIZE: 60 KG, BURN RATE: 69 KG PER HOUR, AVERAGE...
Hiclover provide medical waste incinerators with capacity 10kgs per hour to 500kgs per hour. The incinerator with dual/double combustion chamber...
2 Oil Tank Capacity 200~~ 300 Litre 11 Dual Combustion Chamber with Built in Smoke Filter ( Dry Scrubber )...
HICLOVER offers spare parts Such as: — Burners (diesel oil, LPG or natural gas) — Element for burners — Fire...
It is not meant to use any fuel, such as gas or oil, to promote the burning of the waste,...
HICLOVER now offer a full range of containerized incineration systems, placing us at the forefront of the latest transportation and industrial trends. Containerization enables immediate waste management as the units are pre-assembled and pre-installed.Containerization is the most feasible and viable option in contrast to the construction of on-site facilities and housing structures, eliminating the man power and costs involved. The system has the added benefit of total mobility (both local and international), and is ideal for military and civil camps and remote locations where infrastructure is scarce. Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour...
Brand = Any Model = Any 400v/50hz · Forms of waste – woods, tree branches, tree leaves, wood powder and...