Basic Info. Type:Medical Waste Incinerator Export Markets:Global Additional Info. Trademark:clover Product Description Main Characteristics: 1, Using fever of gasifying combines...
Basic Info. Type:Medical Waste Incinerator Export Markets:Global Additional Info. Trademark:clover Product Description Main Characteristics: 1, Using fever of gasifying combines...
Basic Info. Model NO.:50 kgs per hour Pullution Sources:Solid Waste Processing Processing Methods:Combustion Export Markets:Global Additional Info. Trademark:clover Product Description...
Basic Info. for Animal:All Dosage Form:Incineration Type:Cremation Function:Cremation Export Markets:Global Additional Info. Trademark:nanjing clover Origin:Nanjing Clover Product Description Research and...
Basic Info. Pullution Sources:Solid Waste Processing Processing Methods:Combustion Export Markets:Global Additional Info. Trademark:clover Product Description Items/Model YD-10C YD-20C YD-30C YD-50C...
Basic Info. Model NO.:tempreture of the stoker moving grate incinerator Export Markets:Global Product Description Key Features: * All models with...
WAMBA, Kenya, June 30 (Thomson Reuters Foundation) – Poor weather, security threats and poor roads have made disposing of the...
Items/Model TS50(PLC) Picture Principle Solid Waste Incineration Burn Rate 30-45 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 560L...
Items/Model TS100(PLC) Picture Principle Waste Incineration Treatment Burn Rate 60-80 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 1200L...
Items/Model TS500(PLC) Picture Principle Waste Incineration Treatment Burn Rate 150-200 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 2700L...
Model YD-100 Picture Burning Rate 100-150 kgs/hour Main Combustion Chamber 2000 Liters Secondary Combustion Chamber 500 Liters Feed Mode Manual...
Items/Model TS300(PLC) Principle Waste Incineration Treatment Burn Rate Average 250 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 2000L...
The proposal must include the comprehensive description of the whole system: Total cost of supply, Installation, commissioning, Automatic feeding, automatic...
2. A camera post-combustion gases : Cold filter plugging point -10 ° C max. DIESEL AND FOOD TANK BURNER The...
company. Our products main for small waste output. For hospital straight, local at hospital, or portable/mobile incinerator to a single...
2. What's your minimum capacity and maximum capacity incinerator. 3. You do provide secodn hand incinerator in good working condition....
Disinfecting/sterilizing the contaminated medical wastes, main combustion chamber, post combustion chamber, heat exchanger, ash removal components and flue gas treatment...
50 kg/ hour capacity incinerators · Burning Rate: 50kos/hr · Feed Capacity: 150kqs · Main Combustion Chamber: 900 Dimensions · ...
HICLOVER – Containerized Mobile Incinerator Medical Waste Incinerator Model CA50 Model CA50 Picture Waste Treatment Medical Waste Incineration Treatment Feed Capacity...
HICLOVER – Medical Environmental Model YD-20 Picture Burning Rate Average 20 kgs/hour Feed Capacity Average 60 kgs/feeding Primary Combustion Chamber...
Items/Model CA100 Picture Principle Medical Waste Incineration Treatment Burn Rate Average 100 kg/hour Feed Capacity Average 200kg/feeding Control Mode PLC(Programmable...
Model WS-35 Picture Burning Rate Typical 35 kgs/hour Feed Capacity Typical 80 kgs Primary Combustion Chamber 460 Liters Secondary Combustion...
Items/Model TS30(PLC) Picture Burn Rate Average 30 kg/hour Feed Capacity Average 60kg per feeding Control Mode PLC(Programmable Logic Controller...
Light Weight Small-Scale Medical, Mobile Optional Type Related Incinerator A2400 Medical Waste Incinerator N95 Face Mask Machine Production Line on...
Model Capacity/Burnning Rate For Hospital SickBed No. Fuel Type Qty. Ready for Shipping New Production Shipping Volume Shipping Weight Delivery...
HICLOVER Medical Waste Incinerator in Stock(Finished and Semi-finished and New Production) Model Capacity/Burnning Rate For Hospital SickBed No. Fuel Type...
HICLOVER Medical Waste Incinerator in Stock(Finished and Semi-finished and New Production) Model Capacity/Burnning Rate For Hospital SickBed No. Fuel Type...
HICLOVER Medical Waste Incinerator in Stock(Finished and Semi-finished and New Production) Model Capacity/Burnning Rate For Hospital SickBed No. Fuel Type...
Q: what is kind of waste can use in this equipment?A: This equipment for medical waste, pet animal, Municipal waste, live waste. Prohibit any explosive and radiation material, liquid waste and gas waste. Q: Remedy capacityA: Average Capacity calculated by medical waste(lower calorific power (L.C.P): 3.0TH Kcal/Kg per hour), not mean any waste material. The animal/pet combustion rate around 2/3 of average capacity. Clover incinerator use time daily to 24 hours. Between each feed/combustion time, there are about 0.5-1 hours cooling time and time for feeding waste. Actual combustion time per day is around 16 hours. The lifetime of incinerator between 5-10 year according to use. Generally, we proposal little lab, little clinic use capability under 20 kgs per hour. When incinerator use in hospital, please calculate the waste output capacity around 2kgs per people per day. If there are 200 sickbed in the hospital, that’s mean you need one incinerator capacity around 400kgs per day, change to capacity per hour is around 30-40 kgs per hour. According the operation time per day, waste material, budget, development, etc, you can use capacity from 30-50 kgs per hour incinerator.*How to calculate Animal Cremation Burn Rate: 2/3 of the medical waste. Q: Assembly and TestingA: We provide...
CO – Shouldn't exceed 100 mg/m3 SO2 – Shouldn't exceed 400 mg/m3 HF – (Hydrogen fluoride) Shouldn't exceed 9.0 mg/m3...
it's also very important for us to know whether the unit is qualified to deal with cytotoxic waste and also...
Medical waste is posing a growing problem all around the world, jeopardizing the health of staff, patients, disposal employees and...
HIGH TECH PYROLYTIC MEDICAL WASTE INCINERATOR 1. 21. The de- ashing must be performed in the bottom of the combustion...
Incineration is the most obvious solution for total destruction of municipal waste, avoiding all the direct and indirect risks associated with other disposal methods.Incineration perfectly fits into a trend of treating waste in a safe way, and if possible, at the same place where it was generated to avoid cross-contamination risk and to keep waste treatment costs at acceptable level. — Upgrade/Downgrade Burning Rate WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. ※Main Feature:–Three Combustion Chambers or A/B Main Combustion Chamber— Double or Three Italy Burner–Burning Rate: 80-800kgs per hour–Combustion Chamber: 1.0M3-10.0M3※Optional Function/Parts/Material/Burning Rate: — Stainless Steel Chimney — Dry Smoke Filter Chamber— Chimney Height Custom Made— Semi-Automatic Waste Feeding— 3-Section Wet Scrubber System— Movable Platform Feeding Door— Additional Burner Mobile: +86-13813931455(whatsapp/wechat)Website: www.imclover.com.cn Email: Email: Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC)...
Quantity: Two with complete accessories. Kinds of wastes being used: GENERAL WASTE.Polyester, polypropylene, polystyrene, vinyl acetate plastic, synthetic plastics, –...
HICLOVER, Nanjing Clover Medical Technology Co.,Ltd, supply system solutions for medical environmental protection, animal and pet cremation engineering, other municipal...
Automatic loading and reloading with capacity of 10 to 12 tons per day working with gas treatment procedures and gasoline...
Key Features: General Municipal Solid Waste Incinerator, Pet and Animal Cremation, Containerized Mobile Incinerator, High Efficient Environmental Waste Incinerator.— Single combustion chamber, double combustion chambers, three combustion chambers and multi-combustion chambers waste incinerators.— System solutions for medical waste environmental.— High burn rate, from 5kgs to 1000kgs per hour.— New Design for pet animal cremation business. — HICLOVER, trusted partner with years of experience. WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. — Full range incinerator with Economized Small Scale incinerator, Standard Small-Large Scale incinerator, Mobile: +86-13813931455(whatsapp/wechat)Website: www.imclover.com.cn Email: Email: Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC)...
13. Civil works, installation and Comnuss!Onmg lndusive of civil works (brick wall incinerator house Type of waste for disposal ...
— Full range incinerator with Economized Small Scale incinerator, Standard Small-Large Scale incinerator, General Municipal Solid Waste Incinerator, Pet and Animal Cremation, Containerized Mobile Incinerator, High Efficient Environmental Waste Incinerator. — System solutions for medical waste environmental. — High burn rate, from 5kgs to 1000kgs per hour. — New Design for pet animal cremation business. — HICLOVER, trusted partner with years of experience. Nanjing Clover Medical Technology Co.,Ltd.. Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30...
○ Containerized Mobile Incinerator(CA Model) HICLOVER now offer a full range of containerized incineration systems, placing us at the forefront...
We've got a 70 bed hospital in namibia. However there is a potential of getting clients from other regional doctors....
Requirements and specifications for the process of distribution, installation, operation and guarantee the three incinerators for burning and incineration of...
– 150 KG/HR – Compliant with EU rules, Directive 2000/76/EC – Fuel type: Diesel – Easy management and maintenance...
1. Technical specifications; I. Size of the Incinerator 4,410W x 3,037L x 4,836H mm II. Ability of the Incinerator Medical...
Incinerator but the size of chamber > 2000 x 1200 mm. Prepare for burn LIQUID Waste +/- 20 liter/hr. C:...
1) Electricity Supply: (a) Mains Supply: (I) Single Stage supply; 220 -- 240V, 50Hz (ii) Three Stage supply; 380 --...
2. Heavy duty steel, heat resistant coating, stainless steel lid, painted tubular steel frame, 2-blowers, axial vane, suitable drum (S/S,...
Medical incinerator with a 10 kg/hour (15 lbs/hour) capacity shall be constructed on the site, complete with Stacks, control panels...