HICLOVER Waste Incinerator 10-500kgs/Hr.Double Combustion Chambers
dav

|
HICLOVER Incinerator/Parts Range |
Main Feature |
|
Medical Waste Incinerators |
HICLOVER 10-500kgs/Hr.Double Combustion Chambers |
|
Single Combustion Chamber |
Small, Cheap,10-20kgs/Hr. |
|
Three Combustion Chambers(Optional) |
3 Chambers for high risk waste |
|
Pet Cremation Equipment |
For Pet(small/big) Cremation Business |
|
Animal Incineration Equipment |
For other animal incineration |
|
General Waste Incinerator |
For MSW |
|
Mobile Incinerator(Optional) |
Small-Middle scale, mobile function by 1. )Wheel 2.)DC-Power Trolley 3.)Trailer 4.)Containerized |
|
Wet Scrubber for Smoke Filter(Optional) |
1. ) 1 Section Wet Scrubber 2.)3 Sections Wet Scrubber |
|
1 Section Wet Scrubber |
S.S304 Cooling Spray tower |
|
3 Sections Wet Scrubber |
1.)S.S304 Cooling Spray tower 2.)S.S304 Dust Scrubber 3.) S.S304 Fog and Water Separator |
|
Feeding Door |
1.) Front/Side Manual Loading 2.) Top Feeding Door(Optional) 3.) Auto. Feeding Door(Optional) |
|
3rd Combustion Chamber(Optional) |
|
|
Stainless Steel Main Body(Optional) |
S.S201 or S.S304 |
|
Control Model |
1.) Electric control box(Semi-automatic) 2.) PLC Auto.control box(Automatic) |
|
Light Weight Upgrade(Optional) |
|
|
W2E(Waste to Energy)(Optional) |
Hot Water(Non-drinking water) |
|
Fuel Burner |
Italy Baltur Brand 4.) Both D.O and N.G/LPG(not 2in1 burner, exchange burner type) |
|
Temperature Thermocouple |
1.) K Type,Stainless Steel 1300(Standard) 2.) K Type,Corundum 1300(Optional) 3.) S Type,Platinum Rhodium 1600(Optional) |
|
Control Case Material |
1.) Steel (Standard) 2.) Stailess Steel(Optional) |
|
Chimney/Stack |
1.) Stailess Steel (Standard) 2.) Steel(Optional) 3.)Length(Optional) 4.)Thickness(Optional) |

|
Items/Model |
TS100(PLC) |
TS150(PLC) |
TS300(PLC) |
TS500(PLC) |
|
Burn Rate (Average) |
100 kg/hour |
150 kg/hour |
300 kg/hour |
500 kg/hour |
|
Control Mode |
PLC Auto. |
PLC Auto. |
PLC Auto. |
PLC Auto. |
|
Combustion Chamber |
1200L |
1500L |
2000L |
3000L |
|
Internal Dimensions |
120x100x100cm |
150x100x100cm |
170x120x100cm |
210x120x120cm |
|
Secondary Chamber |
600L |
750L |
1000L |
1500L |
|
Smoke Filter Chamber |
Dry Scrubber |
Dry Scrubber |
Dry Scrubber |
Dry Scrubber |
|
Feed Mode |
Manual |
Manual |
Manual |
Manual |
|
Voltage |
220V |
220V |
220V |
220V |
|
Power |
1.38Kw |
1.69Kw |
2.57Kw |
4.88Kw |
|
Diesel Oil Consumption (kg/hour) |
Ave.20.4 |
Ave.24.2 |
Ave.33 |
Ave.44 |
|
Natural Gas Consumption (m3n/hour) |
Ave.24.5 |
Ave.29 |
Ave.39.6 |
Ave.52.8 |
|
Temperature Monitor |
Yes |
Yes |
Yes |
Yes |
|
Temperature Protection |
Yes |
Yes |
Yes |
Yes |
|
Oil Tank |
200L |
300L |
500L |
500L |
|
Feed Door |
80x60cm |
80x60cm |
|
|
|
Chimney |
10Meter |
10Meter |
14Meter |
14Meter |
|
Chimney Type |
Stainless Steel |
Stainless Steel |
Stainless Steel |
Stainless Steel |
|
1st. Chamber Temperature |
800℃–1000℃ |
800℃–1000℃ |
800℃–1000℃ |
800℃–1000℃ |
|
2nd. Chamber Temperature |
1000℃-1200℃ |
1000℃-1200℃ |
1000℃-1200℃ |
1000℃-1200℃ |
|
Residency Time |
2.0 Sec. |
2.0 Sec. |
2.0 Sec. |
2.0 Sec. |
|
Gross Weight |
6000kg |
8500kg |
11000kg |
16000kg |
|
External Dimensions |
260x150x180cm |
300x160x190cm |
400x210x300cm |
450x210x300cm |
Email: hicloversales@gmail.com
2020-07-27