Best Feeding Door Solid Waste Incinerators HICLOVER
HICLOVER Top Feeding Door Waste Incinerators ▲▲▲Large Feeding Door ▲▲▲Better for Animal Waste Cremation ▲▲▲HICLOVER Brand Section ***Primary Combustion Chamber...
HICLOVER Top Feeding Door Waste Incinerators ▲▲▲Large Feeding Door ▲▲▲Better for Animal Waste Cremation ▲▲▲HICLOVER Brand Section ***Primary Combustion Chamber...
I desire to get back in a lot more technical details e.g. gas use for. Blazing 100/200 kg of animal...
Hospital Waste Management in Addition to Competitive costs as Pakistan is a competitive market. We have a complete setup with...
Resources Of The Wastes. Advanced gas treatment system to avoid discharge of dangerous gases (massaging system). x). Made use of...
Layout CA-200 Picture Burning Rate Regular 100 kgs/hour Key Burning Chamber 2000 Liters Extra Burning Smokeshaft Yes Feed Setting Guidebook...
30kgs rate 60kgs feed oil and gas burner small waste incinerator for Afghanistan Machine Working mode Oil or Gas + Power...
Items/Model TS500( PLC) Photo Principle Waste Incineration Therapy Melt Rate 150-200 kg/hour Control Setting PLC( Programmable Reasoning Control Heater) Combustion...
Items/Model TS100( PLC) Image Concept Waste Incineration Treatment Shed Rate 60-80 kg/hour Control Setting PLC( Programmable Reasoning Controller Burner) Burning...
Items/Model TS50( PLC) Image Principle Strong Waste Incineration Burn Price 30-45 kg/hour Control Mode PLC( Programmable Reasoning Control Heater) Burning...
1. N95 and Disposable Mask Machine 2. 400mm and 1600mm Melt blown Production Line 3. ES Fiber Production Line...
Model CA100 Picture Waste Therapy Medical Waste Incineration Treatment Feed Capacity Ordinary 100-200 kgs per feed Burning Price Typical 100-120...
We are china incinerator manufacturer, contractor and exporter. Manufacturer make reasonable price for incinerator customer, supply medical incinerator, hospital incinerator,...
N95 Face Mask Machine Production Line on Sale Now! $250,000USD per set N95 Face Mask Machine Production Line on Sale...
of primary and secondary air? 7. Is it possible to have an automatic bottom ash unloading system? 9. Is it...
平面口罩机参数: Semi-Automatic Mask Machine l Power supply: 3.3KW mono Stage l Mask Size: 175mm*80-100mm (two or three layers) l Nonwoven (GMS): 10-50g l Capacity: 120...
Dual heat burners and dual chamber incinerator Burning capacity up to 30 Kg per hour Main Product List Primary Combustion...
Burning rate: 250 Kg/hr. It should be able to Operate not Less than 10 hours/day This incinerator must be able...
This equipment quality structural for kinds of site, like hospital, environmental department, animal cremation agencies, etc. HICLOVER Incinerator supply updated...
Temperature Level Show & & & & PLC Control Instance Main Burning Chamber Incinerator Text ***Primary Combustion Chamber Italy Oil/Gas...
Waste Burner (Containerized Mobile Heater) Ability: Normal 50 kgs per human resources Style CA50 Interior Dimensions 100 x 80 x...
Model TS30 oil fired waste small incinerator 30kgs/hr. Items/Model TS30( PLC) Picture Melt Price Average 20-30 kg/hour Feed Capacity Regular...
Waste Incinerator Model TS150 PLC, Overview Construction is dual/double combustion chamber with 02 sets oil burner, batch load incineration equipment....
Key Features: — — — — Complete selection burner with Saved money Tiny Scale burner, Standard Small-Large Range heater, General...
*** 3 sets Burners *** Good for animals or big pets *** Double Combustion chamber *** stainless steel chimney ***...
*** Primary combustion chamber & secondary combustion chamber *** Smoke filter chamber(dry scrubber) *** stainless steel chimney *** PLC auto....
*** Double Combustion Chamber *** PLC auto control operation *** stainless steel chimney *** smoke filter chamber *** Italy oil/gas...
Presently, we supply different series for local customer requirements and design updated incinerator with our leading technology. The updated design feature of our range of incinerators make them one of the most cost effective in the world. Key Features: * All models with Dual combustion chamber. * Stainless Steel chimney/stack, long lifetime. * High temperature, long lifetime of incinerator. * Free or minimum installation on site. * High burn rate, from 10kgs to 600kgs per hour, up to 10ton per day. * PLC Control Plane for Intelligent operation. * New Design for pet animal cremation business. * One year warranty on incinerator and parts in stock. It features unique and advanced merits with compact size, high burning effect, reasonable burning technology, high degree of non-harm etc.It is an ideal choice for waste treatment of hospitals, hotels and various areas. Features: (5) Compact structure and small land occupation. WWW.HICLOVER.COM|Waste Incinerators |Auto Roll...
Smallest waste incinerator for small hospital average 10kgs per hour. with double(2) sets burner. Tools Technical Specifications Version YD-10 Feed...
Merchandise Specification Variation YD-30C (client made version) Main Product List Main Burning Chamber( Text stainless-steel) Second Combustion Chamber( Main body...
Primary chamber:Heavy duty mild steel casing, High quality Refractory lining and insulation 01 x natural gas ignition burners (automatic) 01 x temperature sensor points with complete internal fans.Secondary Chamber:Heavy duty mild steel casing, high quality refractory lining and insulation 01 x natural gas burners (automatic) with complete 01 internal fans. 02 Sec gas residence times.Third Chamber:Heavy duty mild steel casing, high quality refractory lining and insulation 01 x natural gas ignition burners (automatic) with complete internal fans. 02 Sec gas residence time.Integrated dual flu gas washer: Resultant gasses passed through dual gas filtration system for maximum clean emission. It is also equipped with chain filters.Chimney:Heavy duty 5mm or more stainless steel casing mild steel casing.Stack cap/spark arrestors.Control Panel:a.Temperature Monitoring with 4 digit display.b.Thermostat control device for burner (fuel saver)c.Temperature control 0-12 hours.d.Integral fan timer control
Primary chamber:Heavy duty mild steel casing, High quality Refractory lining and insulation 01 x natural gas ignition burners (automatic) 01 x temperature sensor points with complete internal fans.Secondary Chamber:Heavy duty mild steel casing, high quality refractory lining and insulation 01 x natural gas burners (automatic) with complete 01 internal fans. 02 Sec gas residence times.Third Chamber:Heavy duty mild steel casing, high quality refractory lining and insulation 01 x natural gas ignition burners (automatic) with complete internal fans. 02 Sec gas residence time.Integrated dual flu gas washer: Resultant gasses passed through dual gas filtration system for maximum clean emission. It is also equipped with chain filters.Chimney:Heavy duty 5mm or more stainless steel casing mild steel casing.Stack cap/spark arrestors.Control Panel:a.Temperature Monitoring with 4 digit display.b.Thermostat control device for burner (fuel saver)c.Temperature control 0-12 hours.d.Integral fan timer control
Model A1500 (customer made layout ) Interior Measurements 150 x 100 x 96cm Acceptable For Family Pet Feline – –...
It is an auto reader for Bacillus Stearothermophilus to test the spore discharge after treatment (sterilization) of (G) Technical Specifications...
Key Product Checklist Main Burning Chamber Additional Combustion Chamber Mix-Combustion Chamber Smoke Filter Chamber Incinerator Control Circumstance Smokeshaft:5.0 Meters *(...
We complete this job in year 2010 to 2011 and distribution to Hochiminh port, Vietnam with 1×× 40′ feet open...
TECHNICAL INCINERATORS SPECIFICATIONS FOR 2 hospitals All the incinerators to be supplied and installed must meet the Government of...
There are 03 sets Design YD-100 circulation to Iraq between year 2013 to 2014. The heater use for neighborhood a...
Documents to be submitted as following; Fabricators accreditations Test report to prove ZERO harmful emission level provided as samples form...
2nd Chamber (Liters). Items/Model 1000 ℃ -1200 ℃. UNDOUBTEDLY. Mix-Combustion Chamber. 30 kgs/Hr. 200. Outdoors Dimensions (cm). 100x60x60. INDEED. Smoke...
news from: http://www.chinadaily.com.cn/a/202002/01/WS5e347a86a310128217273ead.html THAT proclaims split constitutes global public wellness emergency China guaranteed on Friday to work with the global community...
News from: https://www.thestar.com.my/news/nation/2020/01/26/wuhan-virus-china-mobilises-medical-teams-to-fight-new-coronavirus WUHAN (Bernama): China is mobilising medical staff to aid Wuhan, the centre of the novel coronavirus (2019-nCoV) outbreak,...
———————————– Failure to establish the authenticity of the certificate the bidder is liable to render the bid non-responsive and...
50kgs per hour incinerator with two chambers suppliers from china *Aveage 50kgs per hour *Double chamber and double burner *900liters...
30kgs per hour(average) medical waste incinerator, design dual combustion chambers(primary chamber and secondary chamber), smoke filter chamber, PLC auto. control...
1) Policy – Waste disposal management shall be taken special note to reduce hospital infection. – Infections wastes shall be managed,...
Waste Incinerator Door: Side/Front Opening Door VS. Top Opening Door Things Side Loading Door Top Loading Door Suggestion Price Cheap...
The incinerator shall be equipped with water injection nozzle link. If the temperature in the primary chamber should rise too...
The incinerator shall be supplied with a range of interconnecting ductwork between the thermal reactor outlet and the inlet of...
"PYROLYTIC" combustion, by controlling the gasification of waste The incinerator manufacturer must prevent the discharge of black smoke and fine...